HEATING CONTROL SYSTEM- RTC100

HEATING CONTROL SYSTEM- RTC100

HEATING CONTROL SYSTEM- RTC100

Teaching Experimental Applications (View Data Sheet (pdf))

  • Identification of components of a heating control loop
  • Wiring the inputs and outputs of a heating controller (the connection towards the synoptic can be done manually by double-cords sink or very quickly via a switch that directly connects the two parts)
  • Simulation operation: Connection of controller inputs and outputs to the synoptic table – Real situation operation: connection of inputs outputs of controller towards a compatible complementary bench (optional)
  • Commissioning and adjustment of operating conditions
  • Configuring the controller and verifying the proper operation (heating curve …)

Technical Details (View Specification (docx))

Synoptic of simulation:

  • Synoptic representing a house with two heating regulating circuits (by radiator (x1) and by heated floor (x1)) and a production circuit of DHW.
  • Potentiometers of temperatures simulation (x8) with connection sockets (white and purple): Outer probe, temperature probe ambient room 1, probe ambient room 2, flow probe radiator, flow probe flooring circuit, flow probe boiler, boiler and DHW tank probe
  • Green LEDs for operation status (x11) with connection sockets (brown and black): Burner stage 1, burner stage 2, pump primary circuit, radiator circuit pump, flooring circuit pump, radiator valve circuit (2 lights-opening and closing), valve flooring circuit (2 lights-opening and closing), DHW circulation pump, pump of DHW circulation.
  • Default red lights (x3) with connection sockets (brown and black): Default of primary circuit flow rate, overheating boiler and overheating circuit heated floor.
  • On/Off switches for fault simulation (x3) with connection sockets (black): Default primary circuit flow rate, overheating boiler and overheating circuit heated floor.

Controller:

Heating controller with digital electronic display.

Engraved plate with connection sockets of the inputs. Each socket is marked with the controller input number (ex: B31)

Engraved plate with connection sockets of the outputs. Each socket is marked with the controller input number (ex: K5)

Switches allowing to select the external wiring (manual by cords) or internal (pre established connection)

Switch to turn on with key and white LED voltage presence

Steel console includes a 30mA circuit breaker, magneto thermal circuit breakers, a 230VAC / 24VAC transformer and of relays.

Aluminum profile support chassis equipped with four directional casters with brake and allowing use of the console by a standing man.

The bench with a batch of safety cords allowing to the complete connection of the bench

Dimensions:  (LxWxH mm): 690 x 620 x 1550

weight (Kg): 60

Documentations

  • User Manual
  • Technical documentation of the components
  • Lab exercises
  • Certificate of conformity CE