HOUSE HEATING SYSTEM- TCF200

HOUSE HEATING SYSTEM- TCF200

HOUSE HEATING SYSTEM- TCF200

Teaching Experimental Applications (View Data Sheet (pdf))

– Identification of the components and circuits of a home heating system:

  • Circuit primary heating
  • Secondary circuit floor heating with V3V
  • Secondary circuit radiator with V3V
  • Secondary circuit unit heater with plate exchanger
  • Circuit DHW by tank with exchanger.

– Commissioning of heating installation and verification of operation

– System setup and basic measurement readings (temperatures, pressures, flow rates)

– Advanced measurement and calculation of powers involved and of the consumptions

– Study of heat transfer

– Study of control systems by three-way valve

– Study of the combustion on a burner operating by fuel

Technical Detail (View Specification (docx))

The primary circuit comprises the following elements:

– A boiler working with fuel, power: 22

– An oil burner with forced air

– Two isolation valves of the boiler

– Flowmeter on the outgoing circuit 250-2500L/h

– A dial thermometer 0/120°C on the outgoing circuit

– A mixture bottle of 25L volume with red jacket, drain valve and automatic air vent

– An injection pot with funnel and valves set. Volume 12L

– An expansion tank 25L

– Degasser sludge separator with drain valve in lower part and automatic air vent in the upper part

– Heating safety valve calibrated at 3 bar

– A pressure manometer

– A flow rate control valve (balancing valve type TA)

– Circulator 25-60 with a manometric kit

– A dial thermometer 0/120°C on the return circuit

DHW circuit includes the following elements:

– A DHW tank with exchanger with volume 110L

– DHW circulator with manometric kit

– A flow rate control valve (balancing valve type TA)

– A dial thermometer 0/120°C. at the inlet of the exchanger, at the outlet of the exchanger and tank

– A water supply line with a stop valve, meter, filter, pressure reducing and anti-pollution valves

A cold circuit with flowmeter 100-1000L/h, manometer 0-4 bars and dial thermometer 0/120°C

– A hot water circuit with flowmeter 100-1000L/h, manometer 010 bars and dial thermometer 0/120°C

– A mixer tap mixer – A square stainless steel sink with siphon and overflow

The dissipation circuit N°1 (radiator) includes the following elements:

– Circulator 25-60 with a manometric kit

– A three way valve installed in apportionment

– A flow rate control valve (balancing valve type TA) on the return

– A flow sensor for regulation

– Three dial thermometers 0/120°C

– Two flowmeters 160-1600L /h

– Two bleed valves on the high points of the circuit

– Two quick couplings for connecting of the dissipation systems

Water disposal: at ground level

Evacuation of Smokes : Diameter 125mm

Supply in Fuel: Fuel oil

Dimensions:  (LxWxH mm): 3900 x 1550 x 1900

weight (Kg): 400

Documentations

  • User Manual
  • Electrical Diagram
  • Fluidic Diagram
  • Lab Exercise
  • Technical documentation of the components
  • Certificate of conformity CE